HOME  /  Input/Measuring
Input/Measuring
Power MeasurementSearch
Product Category
Measurement category
Display method
Output signal
Process IndicatorSearch
Product Category
Input signal
Display method
Output signal
Power TransducerSearch
Product Category
Measurement category
Display method
Output signal
Signal ConverterSearch
Product Category
Measurement category
Display method
Output signal
CommunicationSearch
Product Category
Input signal
Output signal
Communication port
Sensor & TransmitterSearch
Product Category
Measurement category
Output signal
Communication port
Data AcquisitionSearch
Product Category
Input signal
Output signal
Energy Management SystemSearch
Product Category
Large DisplaySearch
Product Category
Input signal
Display
Output signal
Phased Out ProductSearch
Product Category
TTI-8

Features

 Input type and range programmable for:

   RTD: Pt100Ω, Cu50

   T/C: K, J, E, T, N, R, S, B

 Output temperature range can be configured by software (requires dedicated cable)

 RS-485 Modbus RTU signal output

TTI-D

Features

 Input type and range programmable for:

   RTD: Pt100Ω, Cu50

   T/C: K, J, E, T, N, R, S, B

 Output temperature range can be configured by software (requires dedicated cable)

 4~20mA Output (2-wire) with loop powered

LS2

Description

LS2 submersible liquid level transmitter adopts the diffusion silicon pressure sensor core of an internationally renowned company. Through highly reliable amplification circuits and precise digital temperature compensation and nonlinear correction technology, the depth of the measured liquid is converted into 4~20mA, RS-485 and other standard digital signals. Fully sealed 304 stainless steel structure, IP68 protection grade. Users can measure the height of various liquids conveniently, quickly and accurately. The ultra-high cost performance can be widely used in petroleum, chemical industry, metallurgy, electric power, complete water supply and other fields.

 

Features

 Digital temperature compensation and non-linear correction.

 High sensitivity, high precision and high stability.

 Cable connection, put directly into the site, easy to install.

 Full temperature zone temperature compensation, good electrical performance and long-term stability.

 The liquid inlet is equipped with a protective cover for easy cleaning and can effectively protect against sand, gravel and sedimentation.

 Two signal outputs, equipped with breathable cables: perfectly solve the gauge pressure error caused by the disconnection between the sensor and the atmosphere.

 The high-performance diffused silicon sensor core is equipped with a highly integrated advanced chip dedicated to bridge pressure sensor signal conditioning.

 

Applications

 Used in an open tank and river ... etc., the sensor can be put in the position of the measured level of the bottom of the lower limit to the upper limit of the water signal

 Drinking water equipment / drilling / wastewater treatment plant / large tank containers / Current water (river, lake)

ADP-33

Description

ADP-30 series of multifunction power meters provide the power monitoring solution especially designed for users' requirement. This power meter combines advanced technology and diverse functions to provide comprehensive power monitoring and management.

With high accuracy measurement for single phase and three-phase system. Measuring parameters for voltage, current, power, power factor, frequency and energy, etc. So the user can control and get an overview of power usage status. Equipped with RS-485 Modbus RTU communication function to facilitate data exchange with other devices or systems to achieve intelligent monitoring and remote management.

In addition to displaying various power parameters, the power meter can also display accumulated electricity bills and CO2 emissions, to help users consider energy consumption and environmental impact more comprehensively.

The ADP-30 series multi-function power meter is a powerful and flexible tool suitable for a variety of application scenarios, including commercial buildings, industrial plants and residential areas. It provides a full range of power management functions, allowing users to manage power resources more intelligently and energy-savingly.

 

Features

■ Measuring 1P2W/1P3W/3P3W/3P4W system and the setting is programmable.

■ Measuring balance unbalance loading system, including power parameters such as voltage, current, frequency, power factor, active power, reactive power, apparent power and energy.

■ The number of sampling cycles is the number of cycles of the input frequency, and each cycle samples 128 points.

■ CT input current can be set 1A or 5A by the user.

■ The large-size, high-brightness LCD is easy and clear to read even under direct sunlight. 

■ Innovative meter AI calculation can perform automatic line adjustment and log it(See Note).

■ Embedded 2MB non-volatile memory(NVM) which is with data and events recording function, can record for a long time.

■ Ethernet Modbus TCP is optional for the second communication. And the dual-port design and daisy-chaining capability remove need for additional switches.

■ Measuring voltage and current up to 31th individual harmonic, and can maintain power stabilty, and moreover, to avoid risk of equipment malfunctiion.

■ Standard with time of use (TOU) function, which can perform power consumption with differential statistics according to the electricity consumption period.

■ Standard with 2 sets of DI and 2 sets of DO, and is designed with a variety of I/O control functions to facilitate on-site monitoring and alarm needs.

■ UL, CE, and FCC certification is in the process of application.

Note: Auto wiring function is conditional, please refer to operation manual.

 

Applications

■ Energy monitoring for motor control panel

■ Energy monitoring for distribution board

■ Energy management and power cost allocation

■ Analysis of energy quality

PD2

Features

 Digital temperature compensation and nonlinear correction.

 High sensitivity, high accuracy and high stability.

 Full temperature range temperature compensation, good electrical performance and long-term stability.

 The plug and shell are integrally spun, stable, reliable and waterproof, preventing the threads of ordinary plugs from loosening.

 Multiple signal outputs, converting the pressure of the measured medium into 4~20mA, 0~10VDC analog signals and RS485 and other standard digital signals.

 With RS485 communication interface, the background system can easily read the measured value.

 The shell is laser welded, which has high reliability, long service life and long-term stability and reliability.

 

Applications

 Pneumatic compressors

 Hydraulic systems

 Pump monitoring

 Oil field equipment and control systems

PU2

Features

 Digital temperature compensation and nonlinear correction.

 High sensitivity, high accuracy and high stability.

 Full temperature range temperature compensation, good electrical performance and long-term stability.

 The plug and shell are integrally spun, stable, reliable and waterproof, preventing the threads of ordinary plugs from loosening.

 Multiple signal outputs, converting the pressure of the measured medium into 4~20mA, 0~10VDC analog signals.

 The shell is laser welded, which has high reliability, long service life and long-term stability and reliability.

 

Applications

 Pneumatic compressors

 Hydraulic systems

 Pump monitoring

 Oil field equipment and control systems

AME

Description

AME uses an ARM Cortex M3 microprocessor to perform the serial port to Ethernet function. It uses state allocation to handle TCP/IP protocol stacking, bringing users lower-cost TCP/IP protocol conversion under limited resources. AME supports TCP, UDP, IP, DHCP client, Modbus/TCP and even HTTP protocols. You can use any browser to set parameters, or use Hyper Terminal in console mode.

 

Features

 RS-485 serial devices can be connected to the Ethernet through simple data conversion to form an Ethernet node.

■ The communication rate can reach 115.2Kbps.

■ When the server side has 4 independent interfaces (Sockets), it can support 4 independent client commands corresponding to respective internal data locations and HTTP protocols, and all commands can be executed at the same time.

 

Applications

Simple and easy to use as a relay converter to convert serial data to Ethernet, it is widely used in factory automation, security protection or any other low-speed data transmission equipment.

 Data collection & security terminals

 Security system equipment

 Warehouse system terminal

 Remote sensors & meters

 Environmental monitors

 Remote equipment control

 Time logger

 Parking lot automation terminal

 Power supply monitoring

 Data collector

 

ACS-13

Description

ACS-13 Single phase power meter (DIN rail) provides accurate metering data of 1P2W or 1P3W for voltage, current, power and energy.

Built-in RS-485 Modbus RTU communication or optional WiFi communicatiion function, allow adminstrators to collect and monitor data of power using remotely.

 

Features

■ Attached wire terminal cover with lead sealing is to protect the wiring connection from unnecessary changes.

■ 1P2W or 1P3W power system can be measured through RS-48 communication. And moreover, 1P2W can measure up to 2 circuits.

■ The number of sampling cycles is the number of cycles of the input frequency, and each cycle samples 128 points.

 

Applications

■ Building Automation

■ Smart Home

■ Store, Martket, Public Place

■ Telecommunication Room

■ Greenhouse Cultivation

■ Campus, Hotel, Laboratory

HTA

Features

Output options: up to 1 set of RS-485 Modbus RTU Communication and 1 set of Analog

selection

Baud rate: 9600, 19200, 38400, 57600, 115200 bps

RS-485 transmission format: N81, N82, E81, O81

RS-485 address: 1~255

RS-485 output response time: <200ms

Temperature and humidity / gas visual compensation deviation values can be corrected

through the RS-485 communication system and key window.

Use laser scattering principal sensors for PM2.5 and PM10

Temperature / Humidity sensing element: CMOS sensor

Analog output options: up to 1 set of 4~20mA or 0~10V output with a specified PM sensor (4 selections)

LCD with 3 backlight colors to indicate concentration levels of PM2.5 or PM10, and the backlight can be factory

specified to corresponding PM option.

3 colors of LCD backlight for corresponding spec: green, blue, orange

Application of HVAC building environmental ventilation and air-conditioning equipment / medical institutions / library /

laboratory / air-conditioned clean room / breeding farm / department store and hotel / cinema and mass rapid transit /

remote real-time monitoring / parking garage / indoor air purification system, etc.

CPM-90

Description

CPM-90 multifunction power analyzer provides high-accuracy measurement and is designed for single phase and three phase application. It includes 4 Digital inputs, 4 Relay outputs, and a RS-485 Modbus RTU Communication port. The user can choose one more communication port, and 2 Analog outputs for output expansion.

 

It provides measure voltage and current of the 2~63 harmonic, and it shows CO2 emissions, which is suitable for power monitoring, management and analyze power quality. It has TOU (time-of-use) function and 4MB Flash memory capacity, allowing users to record data for a long time. It also has a software line adjustment function to reduce the on-site line adjustment work.

It has the functions of waveform capture and recording, power record, and event record, which can be used for multifunction power analyzer.

 

Features

 High Accuracy: 0.2S

 Ethernet communication (Modbus TCP/IP) 

 Swell/ Sag 

 Waveform Capture

 TFT LCD Full color screen

 Sampling rate up to 512 point/cycle

 Power quality Class A IEC61000-4-30

 Plug and play IO module and reverse OEM function for each different application.

 Graphical and Dialogue user interface.

 Customize language menu for each different country.

 Touch Screen operation.

 

Applications

Voltage swell and sag detection record

Power abnormal event record

Waveform capture and recording

Analysis of energy quality

X
Member Login

Forgot your password?
X
Login

Forgot your password?