HOME  /  PRODUCTS  /  Sensor & Transmitter  /  Air Velocity Measurement  /  WSA Duct Type Wind Speed Sensor
WSA Duct Type Wind Speed Sensor
WSA
WSA Duct Type Wind Speed Sensor

Description

Due to environmental quality management and energy management, we've developed WSA, wind speed sensors which can be applied on ventilation systems, air conditioning, and negative pressure rooms. WSA is a high-accuracy duct type wind speed sensor which can quickly measure the small wind speed. It is stable, high-accurate, and with small drift only. Also, it can caculate the value of the current air volume depending on the measured cross-sectional area of the ducting. Ducting installation and screwless terminals help the users work more easily. Besides, the sensor is equipped with EMC anti-interference devices so that it can withstand strong electromagnetic interferences.

 

Features

 High-precision wind speed measurement unit with low start-up wind speed and sensitive response that can be used in harsh environments with ventilation ducts and oil fume ducts

 High accuracy full-scale secondary calibration method demonstrates good linearity

 Open-hole flange construction using high-quality and durable silicone sealing ring to reduce air leakage

 Calculate the value of the current air volume by setting measured cross-sectional area of the ducting

 Using screw-free terminals. No tools are needed for the wiring terminals, just one press and one plug

 Using special EMC anti-interference devices which can withstand strong electromagnetic interferences

 Wind speed mark on the sensor for easy installation

 Power supply with a wide voltage range of 10~30Vdc; long-distance centralized power supply

 Equipped with analog output for AI template; RS-485 outputs for the communication of new systems

 4 setting of measuring range: 0~10m/s, 0~15 m/s, 0~20 m/s (default setting), 0~30 m/s. Adjusted by dip switches

 The accuracy of the setting range for 0~10m/s is ±(0.1+2%FS); for 0~15m/s, 0~20m/s, 0~30m/s are ±(0.2+2%FS) m/s

 Able to set the output signals (4~20mA, 0~5V, and 0~10V)

 Able to choose to go with/without OLED

 

Applications

 New building construction with ventilation system

 Negative-pressure rooms in hospital

 Laboratory

 HVAC

 Vent discharge ducts

Summary of specifications
  • Summary of Specifications
  • Selection Information

DataSheet

Version: 1.0 / Updated: 2024.02.02

 

Manual

Version: 1.1 / Updated: 2024.02.02

X
Member Login

Forgot your password?
X
Login

Forgot your password?