HOME  /  PRODUCTS  /  Process Indicator  /  Digital Panel Meter  /  4 Digits Temperature(RTD) Meter
4 Digits Temperature(RTD) Meter
CM1-TR
4 Digits Temperature(RTD) Meter

Description

 

CM1-TR RTD Temperature Meter has been designed in simple operation and 4 digital 20mm LED display with economic cost. They are can be programmed by buttons that are hidden in front panel. They are also available to option relay output and an analog output or RS485(Modbus RTU Mode) communication.

 

Features

 Measuring RTD type: PT100Ω / PT1000Ω ˙ Unit can be set to or

 The operation buttons are built-in to prevent users from arbitrary operation or incorrect setting, which may cause abnormal operation of the equipment

 The display value can be adjusted slightly with the "field measurement signal"

 The output can option relays or analog output or RS485 (Modbus RTU mode)

 Relay function in addition to start delay, active delay, delay off and active hold

 Analog output voltage signal range can be switched (0~10V/0~5V/1 ~5V) or current signal range can be switched (0~10mA/0~20mA/4~20mA)

 The analog output signal is free to set the corresponding display range (Span-50%) and can be fine-tuned on-site

 On board terminal design, no quality issue; installation depth is only 73mm

 

 

Applications

 With RTD (PT100Ω / PT1000Ω) sensor for temperature display and control.

 Process alarm or communication for data collection.

Summary of specifications
  • Summary of Specifications
  • Selection Information
  • Related Products

Specification & Function

Input:

CM1_TR_Input_EN.jpg

  • Calibration: Digital calibration
  • A/D converter: 14 bits
  • Accuracy: ≤ ± 0 .2℃or ±0.4℉
  • Sampling rate: 15 times / sec
  • Response time: ≤ 100 mS (when avg = “1”)

Display & Function:

  • LED: 4 digits, 0.8”(20.0mm) red high-brightness LED
  • Display range: -1999~+9999
  • Scaling function:
    • [ lOsc]: -199.9~+999.9
    • [ hIsc]: -199.9~+999.9
  • Digital fine adjust:
    • [pVzro]: -199.9~+999.9
    • [pVspn]: -199.9~+999.9
  • Decimal point: [ dp]: 0.0
  • Over range indication: [ ovfl]: when input is over 110% of input range Hi
  • Under range indication: [-ovfl]: when input is under[losc]setting value
  • Max /Mini recording: Maximum and Minimum value storage during running
  • Low cut: [lOcut] -199.9~+999.9 counts

 

Datasheet

Version: 1.3 / Update: 2021.09.03

 

Manual

Version: 1.4 / Update: 2020.09.25

 

Manual-SV

Version: 1.3 / Update: 2018.01.01

 

CM1_TR_Selection_EN.jpg