HOME  /  PRODUCTS  /  Process Indicator  /  Digital Panel Meter  /  4 Digits Process Meter
4 Digits Process Meter
CM1-PR
4 Digits Process Meter

Description

CM1-PR Indicator has been designed in simple function and 4 digital 20.0mm LED displays with economic cost. They are can be programmed by tact switches that are hidden in backside of front bezel. They are also available option of 2 Relay outputs, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of industrial applications.

 

Features

 Measuring 0(1)~5V/0~10V, 0~10mA/0(4)~20mA ( or 2 wire sensor with 24Vdc excitation supply )

 Optional DC24V excitation power for 2 wire sensors

 The operation buttons are built-in to prevent users from arbitrary operation or incorrect setting, which may cause abnormal operation of the equipment

 The display value can be adjusted slightly with the "field measurement signal"

 The output can option relays or analog output or RS485 (Modbus RTU mode)

 Relay function in addition to start delay, active delay, delay off and active hold

 Analog output voltage signal range can be switched (0~10V/0~5V/1 ~5V) or current signal range can be switched (0~10mA/0~20mA/4~20mA)

 The analog output signal is free to set the corresponding display range (Span-50%) and can be fine-tuned on-site

 On board terminal design, no quality issue; installation depth is only 72mm

 

Applications

 2 wire sensing transducers as like as pressure, level and so on…

 Process alarm or communication for data collection

Summary of specifications
  • Summary of Specifications
  • Selection Information
  • Related Products

Specification & Function

Input:

CM1_PR_Input_EN.jpg

  • Calibration: Digital calibration
  • A/D converter: 14 bits
  • Accuracy: ≤ ± 0 .1% of FS ±1 count
  • Sampling rate: 15 times / sec
  • Response time: ≤ 100 mS (when avg = “1”)

Display & Function

  • LED: 4 digits, 0.8”(20.0mm) red high-brightness LED
  • Display range: -1999~+9999
  • Scaling function:
    • [ lOsc]: -1999~+9999
    • [ hIsc]: -1999~+9999
  • Decimal point: Programmable from 0 / 0.0/ 0.00/ 0.000
  • Over range indication: [ ovfl]: when input is over 110% of input range Hi
  • Under range indication: [-ovfl]: when input is under[ losc]setting value
  • Max /Mini recording: Maximum and Minimum value storage during running
  • Low cut: [lOcut] -1999~+9999 counts

Datasheet

Version: 1.1 / Update:2021.12.14

 

Manual

Version: 1.4 / Update: 2020.09.25

 

Manual-SV

Version: 1.3 / Update: 2018.01.01