Features
■ Input Type and range programmable for: RTD PT-100; Thermo-couple type K, J, E, T, R, S, B
■ Output temperature range can be configured by software (Must accompany by programming cable)
■ 4~20mA Output(2-wire) with loop powered
Description
M(x)-5A Power Meter provides power (Watt or Active Power or Re-active Power or Power Factor), high-precision measurement, display and remote communication capabilities.
Additional purchase: 1 group of relay outputs, 1 analog output, an RS485 communication output (the Modbus RTU Mode) interface, so that can be installed in power management, remote input and output, alarm and variety of remote communication control the use of needs.
120mm (D) is ideal for assembling in panels with limited penetration depth.
Features
■ Measuring 1P2W, 1P3W, 3P3W, 3P4W Unbalanced systems of Power Parameters (W、Var、VA、PF.)
■ 1 relay output for Hi / Lo / Hi Hold / Lo Hold / OFF modes, and with start delay, hysteresis, energized time delay, de-energized time delay functions
■ Analogue output and RS 485 communication are available in options
■ Standard panel cutouts: 1/8 DIN 96 x 48 mm
■ Meet CE requirements
Applications
■ Electricity Charging System
■ Energy Consumption Monitoring and control
■ Distribution System
■ Building Automation Energy
■ Management System
■ Testing Equipment
Features
■ Measurement of gauge pressure with high accuracy 0.25%
■ Modularity of electrical and hydraulic connections with stainless sealed
■ Highly resistant to process conditions
■ Low cost & high stability
Applications
■ Pneumatic compressors,
■ Hydraulic systems, pump monitoring,
■ Oil field equipment and control systems
Features
■ Input signal for 4~20mA (with excitation supply available)
■ Output 4~20mA with loop powered, self-powered or auxiliary powered available
■ DIN rail mounting with Ultra slim in 7.6 mm profile
■ CE Approved & RoHS
Features
■ Input signal for 4~20mA (with excitation supply)
■ Output 4~20mA with loop powered, self-powered or auxiliary powered available
■ DIN rail mounting with Ultra slim in 7.6 mm profile
■ CE Approved & RoHS
Features
■ Input Type and range programmable for RTD PT-100; Thermo-couple type K, J, E, T, R, S, B
■ Output 4~20mA with loop powered, self-powered or auxiliary powered available
■ DIN rail mounting with Ultra slim in 7.6 mm profile
■ CE Approved & RoHS
● A wide range selectable to meet various application
● 230K~300Khr. MTBF
● RoHS version in option
● Compact size with DIN rail mounting
Features
■ 4 Popular Input Ranges Programmable in One
■ Modular Design, Easy Maintain and Save Stock;
■ Dual trip relay output available
■ Low cost & high stability
● Universal power AC90~264V/DC127~380V
● Build in power factor control circuit in high power model(120W~500W)
● Available for series and parallel operation
● To be a Back up power function with relay output in option( not available in model 20W and 24W)
● RoHS & UL version in option
● DIN rail mounting
Features
■ 4 popular Input and 8 Output Ranges Programmable by dip switches
■ Dual isolated output is available
■ Low cost & high stability
Description
AQW series was designed for air quality measure, such as PM2.5, Ch20, CO2, temperature and humidity. Use high-precision sensor to ensure long-term stability and reliability of the instrument. Panel with large LCD display, easy to read the measuring value. And also have 4 LED indicator to indicate air quality status and device running. AQW series communication port is WiFi, it’s convenient for data collect, support Modbus TCP protocol, and others cloud protocol.
Applications
■ Production Line, Warehouse, Public Places, Intelligent Building Smart Home, Building Automation air quality monitoring
Features
■ 10 popular Inputs and 4 popular Output (Programmable by dip switches) Ranges
■ Modular Design, Easy Maintain and Save Stock;
■ Changeable Output Module Between V/mA, Trip Relay with difference programming module
■ Dual difference signal output available even for trip relay
■ Low cost & high stability
Features
■ 8 Outputs Range Programmable by dip switches
■ Modular Design, Easy Maintain and Save Stock;
■ Dual pulse output available
Description
LS submersible liquid level transmitter adopts the diffusion silicon pressure sensor core of an internationally renowned company. Through highly reliable amplification circuits and precise digital temperature compensation and nonlinear correction technology, the depth of the measured liquid is converted into 4~20mA, RS-485 and other standard digital signals. Fully sealed 304 stainless steel structure, IP68 protection grade. Users can measure the height of various liquids conveniently, quickly and accurately. The ultra-high cost performance can be widely used in petroleum, chemical industry, metallurgy, electric power, complete water supply and other fields.
Features
■ Digital temperature compensation and non-linear correction.
■ High sensitivity, high precision and high stability.
■ Cable connection, put directly into the site, easy to install.
■ Full temperature zone temperature compensation, good electrical performance and long-term stability.
■ The liquid inlet is equipped with a protective cover for easy cleaning and can effectively protect against sand, gravel and sedimentation.
■ Two signal outputs, equipped with breathable cables: perfectly solve the gauge pressure error caused by the disconnection between the sensor and the atmosphere.
■ The high-performance diffused silicon sensor core is equipped with a highly integrated advanced chip dedicated to bridge pressure sensor signal conditioning.
Applications
■ Used in an open tank and river ... etc., the sensor can be put in the position of the measured level of the bottom of the lower limit to the upper limit of the water signal
■ Drinking water equipment / drilling / wastewater treatment plant / large tank containers / Current water (river, lake)
Description
CPM-10 Multifunction Power meter measures single phase 2 wire ,single phase 3 wire, three phase 3 Wire and 3 Phase 4 wire systems with high accuracy measurement for parameters such as voltage, current ,active power, reactive power, apparent power, power factor ,frequency, effective energy (V,A,W,Watt-Hr,Var,Var-Hr,VA,PF,Hz), having LED display and standard communication RTU Modbus RS485..
Optional functions 1 set relay output,1 analogue,1 RS485 (ModbusRTU Mode) or 1 pulse output. Most suitable for power management,remote input /output, alarm and remote signal control uses needs.
Case depth 120mm only, easy panel mounting installation.
Features
■ Measure 1P2W,1P3W,3P3W,3P4W Unbalanced/Balanced load system’s active power, reactive power, apparent power and electric energy (Watts-Hr) etc parameters.
■ Dual display, upper row 4 digits and voltage/ 4 digits for current ( or 10 digits Watts-Hr),lower row 4 1/2 digits Watts. (0~29999)
■ 1 set relay(SPDT) output, with 3 variable setting (R1.1/R1.2/R1.3), can be set to below parameters V.AVG/I.AVG/FREQ/P.TL/Q.TL/ S.TL / PF.AVG / AE.TL / RE.TL / VA / VB / VC / IA / IB / IC / PF-A / PF-B / PF-C / P-A / P-B / P-C / Q-A / Q-B / Q-C / S-A / S-B / S-C, having relay function : Hi / Lo / Hi Hold / Lo Hold / OFF; further advance function , start delay, hysteresis, time delay, reset delay etc
■ 1 analogue output same as relay setting parameters. Selectable output range for voltage or currents
■ Output ranges for Current 0~10mA / 0~20 mA / 4~20 mA / 4~±20 mA / ±10 mA / ±20 mA (Default 4-20mA)
■ Output ranges for Voltage 0~5V / 1~5 V / 0~10 V / 0~±5 V / 1~±5 V / 0~±10 V / ±5 V / ±10 V (Default 0-10V)
■ Option pulse or RS 485 communication output.
■ Outer case standard DIN 96 x 48 mm
■ CE approved
Applications
■ Motor control / panel power monitoring
■ Power consumption monitor and control
■ Power distribution system
■ Intelligent building & automation power management system
■ Power testing equipment
Description
MWH-10A Energy Meter offers high accuracy measurements of Energy (Watt-Hr) and Active Power, display and communication functions. It is also with 1 relay output, 1 analogue output, 1 RS485 communication port, and 1 pulse output in option as well 112mm (D) is ideal for assembling in panels with limited penetration depth.
Features
■ Measure Watt & Watt-hr in 1P2W,1P3W,3P3W,3P4W Unbalanced systems
■ Dual display for 10 digits Watts-Hr and 4 2/3 digits Active Watts
■ 1 relay output for Hi / Lo / Hi Hold / Lo Hold / OFF modes; and with start delay, hysteresis, energized time delay, de-energized time delay functions
■ Analogue output, pulse and RS 485 communicationare available in options
■ Standard panel cutouts: 1/8 DIN 96 x 48 mm
■ Meet CE requirements
Applications
■ Control panels and Consumption monitoring
■ Switchgear distribution system
■ Energy and tariff managements for building automation
■ Energy Testing Equipment
Features
■ Measurement T/C, Pt100Ω, Process signals mA, Vdc
■ Accuracy: Full scale +/-0.5%
■ 4-digit display;Display range: -1999~9999
■ Standard with automatic / manual output
■ Optional heating / cooling control output
■ Optional analog signal transfer function
■ Dimensions can choose DIN 1/4, 1/8, 1/16
■ High stability and low cost
Description
Provide high accuracy DC power measurement, display and remote communication up to eight loops. Multi-circuit design decreases the overall cost and make the functionality more flexible. All remote monitored data is available via a RS-485 Communication. So the possible reduced output can be detected immediately that allowing quickly repairs for defective panels. Moreover, it will helps panels in high DC system to optimize the performance and reduce the down-time.
Features
■ Metering parameters of Voltage, Current, Active Power, Energy (Watt-Hr) of DC power system.
■ For local display, and connected with industrial control equipment, computers, to form a measurement and control system.
■ Monitor individual strings with up to 8 inputs and a max 20 A per input.
■ Enables the measurement of 20 A per input even at 70℃ with a precision of ±1 % (voltage/current).
■ With standard RS-485 serial for remote controlling relay output, RS-485 SPD embedded on board with surge protection design for RS-485.
■ CE Approved.
■ Embedded 1MB flash memory for Data-Logging.
Applications
■ Status monitoring of solar panel
■ Status monitoring of DC panel
■ Status monitoring of charging posts
■ Status monitoring of telecommunications base stations