Description
PN-DNet uses ASIX family microprocessor for implementing Ethernet functions (DI/DO TO Ethernet)。It uses the state machine to handle TCP/IP stack with most but limited functions because of the limited resources。 PN-DNet supports TCP、UDP、IP、DHCP-Client、Modbus/TCP even HTTP protocols。You can use any browsers to set the parameters, or just use the commands in console mode.
Features
■ Supports TCP/IP, UDP, DHCP, HTTP, Modbus/TCP, and 10/100 Base-T Ethernet standard
■ Supports Based interface for fast configuration without special software, also command mode for parameters setting by application software
■ Supports Modbus/TCP for easy integration with HMI/SCADA or OPC server
■ 12 DI input channels and 6 DO output channels
■ Input / Output with optical isolation, pressure 3000 Volts
■ Input function: support input counts or input frequency functions, and supports dry contact or Voltage pulse (30V ,7mA)
■ Built-in watchdog timer automatic reversion
■ Built-in transient voltage suppressor (TVS) and electrostatic discharge (ESD) protection
Applications
It is easy to convert DI status and DO control to Ethernet in IA, Factory Automation, Security or any other low data rate data transmission by using it as the intermediate converter.。
■ Security devices
■ Warehouse terminals
■ Access control terminals
■ Time recorders
■ Shop floor automation terminals
Description
PL-DTS is an I/O controller product with Serial Port on its data communication and makes data acquisition easier through Modbus Protocol of RTU mode on Serial Bus. PL DTS uses the ARM Cortex - -M3 microprocessor family for implementing the whole framework. Basically, it supports up to 10 inputs and 8 outputs or 18 inputs. Moreover, it equips the counter function in each input channels, and is also designed for friendly use and convenience concerns.
Features
■ Support Modbus Protocol Auto Detect ModBus RTU and ASCII Mode Supported Modbus Function 01, 02, 03, 04, 05, 06, 0F, 10
■ Configurable Parameters with Device ID Control Configurable under Console Mode Enable / Disable: When Device ID Control is enabled, it will reply the modbus requests only when the Device ID is correct
■ Each Input will enable Counter Function simultaneously when DIP Switch select to enable Counter Function
Applications
It is easy to convert DI status and DO control to Ethernet in IA, Factory Automation, Security or any other low data rate data transmission by using it as the intermediate converter.。
■ Security devices
■ Warehouse terminals
■ Access control terminals
■ Time recorders
■ Shop floor automation terminals