Description
PA-MTS is an analog signal serial data controller product, through Modbus RTU mode's universal protocol, making data collection and control more convenience PA-MTS uses Microchip DS PIC as main design structure. Equip with 8 or 16 Channel common ground analog input, all channel isolated type is also available
Features
■ Support Modbus communication protocol Support Modbus function 03, 06
■ With Display for easy parameters and equipment ID setting
■ 16 Channel common ground model and 14 Bits A/D Converter
■ 4 Types of Signal: Voltage:0~10V/(0)1~5V or Current:0(4)~20mA, RTD(PT100Ω),Thermocouple(K,J,E,T) Type.
Applications
Factory automation machineries, low speed process signal or temperature signal can be easily converted from analog to RS485 protocol for data analysis
■ Analog data collector
■ Remote sensing and metering
■ Environment condition detection
■ Data recording
Description
PN – ANET is an I/O controller product with Ethernet Port on its data communication and makes data acquisition easier through Modbus/RTU or Modbus/TCP Protocols. PN - ANET was designed for voltage and current measurement。And uses the derivatives ASIX microprocessor for implementing the whole framework. A / D value is 16-bit effective resolution. it equips 8 channels of single-ended analog input and two digital outputs in a set.
Features
■ Supports TCP/IP, UDP, DHCP, HTTP, Modbus/TCP, and 10Base-T Ethernet standard
■ Supports Based interface for fast configuration without special software, also command mode for parameters setting by application software
■ Supports Modbus/TCP for easy integration with HMI/SCADA or OPC server
■ 8 single ended input channels with 16bits A/D converter with optical isolation
■ Four models for Voltage: ±150mV、±500mV、0~5V、±10V/,or Current: 0~20mA、4~20mA
■ Each analog channel, you can set a separate range for various applications
Applications
It is easy to convert AI and DO control to Ethernet in IA, Factory Automation, Security or any other low data rate data transmission by using it as the intermediate converter.
■ Data collection
■ Remote Sensors and Various Meters
■ Access control terminals
■ Environmental monitors
■ Data loggers
Description
PL-ATS is an I/O controller product with Serial Port on its data communication and makes data acquisition easier through ModBus Protocol of RTU mode on Serial Bus. It use the 8051’s family microprocessor for implementing the whole framework. Basically, it equips 8 channels of single-ended analog input and two digital outputs in a set.
Features
■ Support ModBus Protocol X Auto Detect ModBus RTU and ASCII Mode X Supported Modbus Function 01, 02, 03, 04, 05, 06, 10, 0F
■ Configurable Parameters with Device ID Control X Configurable under Console Mode X Enable / Disable: When Device ID Control is enabled, it will reply the modbus requests only when the Device ID is correct
■ Input abnormal Detection: Flag will be set while the input voltage or current got lower than low range or higher than high range
■ 8 single ended input channels with 16bits A/D converter with optical isolation
■ Four models for Voltage: 0~10V/1~5V or Current: 0~20mA/4~20mA by dip-switch changeable
Applications
It is easy to convert AI and DO control to Ethernet in IA, Factory Automation, Security or any other low data rate data transmission by using it as the intermediate converter.
■ Data collection
■ Remote Sensors and Various Meters
■ Access control terminals
■ Environmental monitors