HOME  /  PRODUCTS  /  Power Measurement  /  Multifunction Power Meter
Multifunction Power Meter
ADP-33

    Description

    ADP-30 series of multifunction power meters provide the power monitoring solution especially designed for users' requirement. This power meter combines advanced technology and diverse functions to provide comprehensive power monitoring and management.

    With high accuracy measurement for single phase and three-phase system. Measuring parameters for voltage, current, power, power factor, frequency and energy, etc. So the user can control and get an overview of power usage status. Equipped with RS-485 Modbus RTU communication function to facilitate data exchange with other devices or systems to achieve intelligent monitoring and remote management.

    In addition to displaying various power parameters, the power meter can also display accumulated electricity bills and CO2 emissions, to help users consider energy consumption and environmental impact more comprehensively.

    The ADP-30 series multi-function power meter is a powerful and flexible tool suitable for a variety of application scenarios, including commercial buildings, industrial plants and residential areas. It provides a full range of power management functions, allowing users to manage power resources more intelligently and energy-savingly.

     

    Features

    ■ Measuring 1P2W/1P3W/3P3W/3P4W system and the setting is programmable.

    ■ Measuring balance unbalance loading system, including power parameters such as voltage, current, frequency, power factor, active power, reactive power, apparent power and energy.

    ■ The number of sampling cycles is the number of cycles of the input frequency, and each cycle samples 128 points.

    ■ CT input current can be set 1A or 5A by the user.

    ■ The large-size, high-brightness LCD is easy and clear to read even under direct sunlight. 

    ■ Innovative meter AI calculation can perform automatic line adjustment and log it(See Note).

    ■ Embedded 2MB non-volatile memory(NVM) which is with data and events recording function, can record for a long time.

    ■ Ethernet Modbus TCP is optional for the second communication. And the dual-port design and daisy-chaining capability remove need for additional switches.

    ■ Measuring voltage and current up to 31th individual harmonic, and can maintain power stabilty, and moreover, to avoid risk of equipment malfunctiion.

    ■ Standard with time of use (TOU) function, which can perform power consumption with differential statistics according to the electricity consumption period.

    ■ Standard with 2 sets of DI and 2 sets of DO, and is designed with a variety of I/O control functions to facilitate on-site monitoring and alarm needs.

    ■ UL, CE, and FCC certification is in the process of application.

    Note: Auto wiring function is conditional, please refer to operation manual.

     

    Applications

    ■ Energy monitoring for motor control panel

    ■ Energy monitoring for distribution board

    ■ Energy management and power cost allocation

    ■ Analysis of energy quality

ACS-13

    Description

    ACS-13 Single phase power meter (DIN rail) provides accurate metering data of 1P2W or 1P3W for voltage, current, power and energy.

    Built-in RS-485 Modbus RTU communication or optional WiFi communicatiion function, allow adminstrators to collect and monitor data of power using remotely.

     

    Features

    ■ Attached wire terminal cover with lead sealing is to protect the wiring connection from unnecessary changes.

    ■ 1P2W or 1P3W power system can be measured through RS-48 communication. And moreover, 1P2W can measure up to 2 circuits.

    ■ The number of sampling cycles is the number of cycles of the input frequency, and each cycle samples 128 points.

     

    Applications

    ■ Building Automation

    ■ Smart Home

    ■ Store, Martket, Public Place

    ■ Telecommunication Room

    ■ Greenhouse Cultivation

    ■ Campus, Hotel, Laboratory

CPM-90

    Description

    CPM-90 multifunction power analyzer provides high-accuracy measurement and is designed for single phase and three phase application. It includes 4 Digital inputs, 4 Relay outputs, and a RS-485 Modbus RTU Communication port. The user can choose one more communication port, and 2 Analog outputs for output expansion.

     

    It provides measure voltage and current of the 2~63 harmonic, and it shows CO2 emissions, which is suitable for power monitoring, management and analyze power quality. It has TOU (time-of-use) function and 4MB Flash memory capacity, allowing users to record data for a long time. It also has a software line adjustment function to reduce the on-site line adjustment work.

    It has the functions of waveform capture and recording, power record, and event record, which can be used for multifunction power analyzer.

     

    Features

     High Accuracy: 0.2S

     Ethernet communication (Modbus TCP/IP) 

     Swell/ Sag 

     Waveform Capture

     TFT LCD Full color screen

     Sampling rate up to 512 point/cycle

     Power quality Class A IEC61000-4-30

     Plug and play IO module and reverse OEM function for each different application.

     Graphical and Dialogue user interface.

     Customize language menu for each different country.

     Touch Screen operation.

     

    Applications

    Voltage swell and sag detection record

    Power abnormal event record

    Waveform capture and recording

    Analysis of energy quality

AFM-8A

    Description

    AFM-8A has Developed for AFC*(Auto Frequency Control) high performance measurement and frequency update, its update up quicker than 100mSec. multifunction power analyzer provides high-accuracy measurement and is designed for single phase and three phase application. It includes 4 Digital inputs, 4 Relay outputs, and a RS-485 Modbus RTU Communication port. The user can choose one more communication port, and 2 Analog outputs for output expansion.

    It provides measure voltage and current of the 2~63 harmonic, and it shows CO2 emissions, which is suitable for power monitoring, management and analyze power quality. It has TOU (time-of-use) function and 4MB Flash memory capacity, allowing users to record data for a long time. It also has a software line adjustment function to reduce the on-site line adjustment work.

     

    *Automatic Frequency Control (AFC) frequency modulation service is one of the emerging technologies, because the energy storage system has the characteristics of rapid charging and discharging, through the active adjustment of the charging and discharging action to adjust the frequency of the power system, it can help maintain the frequency drift caused by load fluctuations, which is very suitable as a system stability response scheme under the high proportion of renewable energy.

     

    Features

     Measuring 1P2W/1P3W/3P3W/3P4W system and the setting is programmable.

     Measuring balance / unbalance loading system, including power parameters such as voltage, current, frequency, power factor, active power, reactive power, apparent power and energy.

     CT input current can be set 1A or 5A by the user.

     The number of sampling cycles is the number of cycles of the input frequency, and each cycle samples 256 points.

     The large-size, high-brightness LCD is easy and clear to read even under direct sunlight.

     Innovative meter AI calculation can perform automatic line adjustment (See Note).

     Embedded 4MB non-volatile memory(NVM) which is with data and events recording function, can record for a long time.

     Measuring power quality is optional, for recording voltage sag, voltage surge and current swell event which included the time stamp and setting value.

     RS-485 Modbus RTU or Ethernet Modbus TCP is optional for the second communication.

     Measuring voltage and current up to 63th individual harmonic, and can maintain power stability, and moreover, to avoid risk of equipment malfunctiion.

     Standard with time of use (TOU) function, which can perform power consumption with differential statistics according to the electricity consumption period.

     Standard with 4 sets of DI and 4 sets of relay output, or choose option with 8 sets of DI and 2 sets of AO for the control functions to facilitate on-site monitoring and alarm needs.

     Standard with 1 set of RS-485 Modbus RTU, and it's optional for one more set of RS-485 or Ethernet interface (Modbus TCP).

     CE, and FCC approved.

     Up to 9 parameters with 20Hz (50ms) of data refresh rate.

    Note: Auto wiring function is conditional, please refer to operation manual.

     

    Applications

     Automatic frequency control

     Swell and sag detection record

     Power abnormal event record

     Waveform capture and recording

CPM-80

    Description

    CPM-80 multifunction power analyzer provides high-accuracy measurement and is designed for single phase and three phase application. It includes 4 Digital inputs, 4 Relay outputs, and a RS-485 Modbus RTU Communication port. The user can choose one more communication port, and 2 Analog outputs for output expansion.

    It provides measure voltage and current of the 2~63 harmonic, and it shows CO2 emissions, which is suitable for power monitoring, management and analyze power quality. It has TOU (time-of-use) function and 4MB Flash memory capacity, allowing users to record data for a long time. It also has a software line adjustment function to reduce the on-site line adjustment work.

    It has the functions of waveform capture and recording, power record, and event record, which can be used for multifunction power analyzer.

     

    Features

     Measuring 1P2W/1P3W/3P3W/3P4W system and the setting is programmable.

     Measuring balance / unbalance loading system, including power parameters such as voltage, current, frequency, power factor, active power, reactive power, apparent power and energy.

     CT input current can be set 1A or 5A by the user.

     The number of sampling cycles is the number of cycles of the input frequency, and each cycle samples 256 points.

     The large-size, high-brightness LCD is easy and clear to read even under direct sunlight.

     Innovative meter AI calculation can perform automatic line adjustment (See Note).

     Embedded 4MB non-volatile memory(NVM) which is with data and events recording function, can record for a long time.

     Measuring power quality is optional, for recording voltage sag, voltage surge and current swell event which included the time stamp and setting value.

     RS-485 Modbus RTU or Ethernet Modbus TCP is optional for the second communication.

     Measuring voltage and current up to 63th individual harmonic, and can maintain power stability, and moreover, to avoid risk of equipment malfunctiion.

     Standard with time of use (TOU) function, which can perform power consumption with differential statistics according to the electricity consumption period.

     Standard with 4 sets of DI and 4 sets of relay output, or choose option with 8 sets of DI and 2 sets of AO for the control functions to facilitate on-site monitoring and alarm needs.

     Standard with 1 set of RS-485 Modbus RTU, and it's optional for one more set of RS-485 or Ethernet interface (Modbus TCP).

     CE, and FCC approved.

    Note: Auto wiring function is conditional, please refer to operation manual.

     

    Applications

    ■ Voltage swell and sag detection record

    ■ Power abnormal event record

    ■ Waveform capture and recording

    ■ Analysis of energy quality

CPM-70

    Description

    CPM-70 multifunction power analyzer provides high accuracy single phase and three-phase energy measuring and displaying, energy accumulating, power quality analysis, data logging and data communication.

    CPM-70 series meters are able to measure bidirectional, four quadrants kWh and kVarh.

    It provides maximum/minimum records for power usage and power demand parameters. Hardware standard built in a RS485 Modbus communication port , 4 Digital inputs, 2 Relay outputs, LCM and 2 MB flash for data-logging.

    In addition , also provide TOU , voltage and current THD, harmonics up to the 51st and auto wiring change (Note) via software.

     

    Features

    Sampling 128 point / cycle

    ■ High Accuracy: 0.5S

    Individual harmonic 2~51st

    Demand, electricity bill, CO2 carbon emission accumulation

    ■ FCC, CE certified

     

    Applications

    ■ Energy management system

    ■ Intelligent power panel

    ■ Community power monitoring

    ■ Power Grid automation

    ■ Industrial automation

    ■ Intelligent green building

CPM-20

    Description

    CPM-20 multifunction power meter with high accuracy measurement for single phase and three-phase system. Measuring parameters for voltage, current, active/reactive/apparent power and energy, power factor, and frequency etc.. Standard with RS-485 Modbus RTU communication port, front LCD display with buttons for programming. It can display the accumulated CO2 emission for power monitoring and management.

     

    Features

    ■ With reliability simulation test report of MTBF over 60,000 hours.

    ■ Auto wiring change (Note) via software.

    ■ High brightness display. Able to perform even in direct sunlight.

    ■ RS485 Modbus RTU, the highest baud rate can reach 115200bps; data error rate below 1%

    ■ FCC, CE certified

     

    Applications

    ■ Energy monitor of motor control panel / distribution board

    ■ Energy management / electric cost allocation

    ■ Intelligent power panel

    ■ Community power monitoring

    ■ Intelligent green building

CPM-12

    Description

    CPM-12 multi-functional power meter provides high accuracy measurement (the parameter of single-phase and three-phase), display, RS485 Modbus communication, and can display accumulated CO2 emission. Measuring parameters for voltage, current, active/reactive/apparent power and energy, power factor, and frequency etc..

     

    Features

    ■ With reliability simulation test report of MTBF over 60,000 hours.

    ■ Auto wiring change (Note) via software.

    ■ High brightness display. Able to perform even in direct sunlight.

    ■ RS485 Modbus RTU, the highest baud rate can reach 115200bps; data error rate below 1%

    ■ FCC, CE certified

     

    Applications

    ■ Energy monitor of motor control panel / distribution board

    ■ Energy management / electric cost allocation

    ■ Intelligent power panel

    ■ Community power monitoring

    ■ Intelligent green building

CPM-12D

    Description

    CPM-12D is a din rail mounting multifunction power meter with high accuracy measurement for single phase and three-phase system.

    Measuring all basic parameters ; V, I, P, Q, kWh, kVarh etc..

     

    Features

    ■ Measurement: True RMS

    ■ Sampling: 128 point/Cycle

    ■ Metering system type: 1P2W, 1P3W, 3P3W(1/2/3CT)、3P4W(1/3CT);Balance / Unbalance

    ■ 1 RS485 Modbus RTU communication port as default,

    ■ LCD display in front panel with buttons for programming.

    ■ Auto wiring change (see remark as below) via software

    ■ CE and FCC approved

    Remark: Auto wiring change have certain condition limit, please refer to operation manual for further details.

     

    Applications

    ■ Energy management system

    ■ Factory automation

    ■ Intelligent power panel

    ■ Industrial automation

    ■ Machinery power consumption

    ■ Community power monitoring

    ■ Intelligent green building

CPM-10B

    Description

    CPM-10B Multifunction Power meter measure single phase 2 wire, single phase 3 wire, three phase 3 Wire and 3 phase 4 wire systems with high accuracy measurement for parameters such as voltage, current, active power, reactive power, apparent power, power factor, frequency, active energy (V, A, W, Watt-Hr, Var, Var-Hr, VA, PF, Hz), having LED display and standard communication port.

     

    Standard with 1 set of RS-485 Modbus RTU port, and optional for 1 set of relay output, pulse output or analog output, so as to satisfy any application for power management, remote input / output, alarm and remote signal control needs. Case depth 120mm only, easy panel mounting installation.

     

    Features

     Measure 1P2W, 1P3W, 3P3W, 3P4W Unbalanced / Balanced load system's active power, reactive power, apparent power and electric energy (Watts-Hr) etc parameters.

     Dual display, upper row shows 4 digits voltage and 4 digits current (or 10 digits Watts-Hr), lower row shows 4 1/2 digits Watts. (0~29999)

     1 set relay output, with 3 variable setting, can be set to below parameters V.AVG / I.AVG / FREQ / P.TL / Q.TL / S.TL / PF.AVG / VA / VB / VC / IA / IB / IC / PF-A / PF-B / PF-C / P-A / P-B / P-C / Q-A / Q-B / Q-C / S-A / S-B / S-C, having relay function: Hi / Lo / Hi Hold / Lo Hold / OFF, further advance function, start delay, hysteresis, delay On,

    delay Off etc.

    1 analog output same as relay setting parameters. Selectable output range for voltage or currents Output ranges for Current 0~10mA / 0~20 mA / 4~20 mA / 4~12~20 mA / ±10 mA / ±20 mA (Default 4~20 mA) Output ranges for Voltage 0~5V / 1~5 V / 0~10 V / 0~2.5~5 V / 1~3~5 V / 0~5~10 V / ±5 V / ±10 V (Default 0~10V)

    Standard with 1 set of RS-485 communication output, optional for 1 set of relay, pulse, or analog output.

     Outer case standard DIN 96 x 48 mm

     CE approved

     

    Applications

    ■ Motor control / panel power monitoring

    ■ Power consumption monitor and control

    ■ Power distribution system

    ■ Intelligent building & automation power management system

    ■ Power testing equipment

VAW

    Description

    VAW DC Power Meter provides high accuracy measurement, display and communication of DC voltage, Current, Power, Energy(import / export), and Run Hour. They are also building in 4 Relay outputs, 1 Analogue output, 1 Pulse output, 2External Control Inputs and 1 RS485(Modbus RTU Mode) interface with versatile functions such as remote I/O, alarm and communication for DC power applications like as solar, wind power system or portable electronic device consumption testing.

    For the power saving, VAW has built in an innovation timer to switch down the light and power of LED. It makes sense to build the meter in a green power system.

     

    Features

    ■ Measuring DC Voltage, Current, Power, Import Energy and Export Energy

    ■ 4 relays can be multi-cross programmed individual to correspond,

    Voltage/Current/Power(kW): Hi / Lo / Hi Latch / Lo Latch energized with Start Delay / Hysteresis / Energized

    & De-energized Delay functions.

    Energy(kWh): Energized with N/R/C mode

    Other application: DO (Digital output)

    ■ 2 external control inputs can be programmed individual to correspond,

    Voltage/Current/Power(kW): Relative PV (Tare) / PV Hold / Maximum or Minimum Hold

    Energy(kWh): Gate / Reset

    Other application: DI(remote monitoring) / Reset for Relay Energized Latch

    ■ Analogue multi-cross selection for Voltage/Current/Power(kW)/Energy output in option

    ■ Pulse output to correspond energy and RS 485 communication port in option

    ■ Outside dimensions is DIN standard (96 x 48 mm)

    ■ CE Approved & RoHS

     

    Applications

    Solar system monitoring