HOME  /  PRODUCTS  /  Process Indicator  /  Digital Panel Meter
Digital Panel Meter
CS2-TM-Analogue

    Description

    The CS2-TM Totalizer controller provide high accuracy measurement, display, control and communication (Modbus RTU mode) of 0~10V/4~20mA from flow meter or mV from Shunt for Amp-Hour. There are two display screen and 3 external control input (DI) in standard and the optional 4 Relay, 1 Analogue, 1 Pulse and RS485 port available. They are also supporting fantastic control function as like as N, R, C mode for totalizer and batch control.

     

    Features

     Measuring DC signal 0 ~ 10V or 0(4) ~ 20mA (with square root function) from flow meter or 0~50/~60/ ~100mV from Current Shunt for Amp-Hour control.

     Dual display screen for 10 digital Totalizer or Batch counter + 4 2/3 Immediate Value (PV) or 6 digital Batch programmable.

     4 banks pre-set for all relay functions relative 4 difference scaling, and selectable by 3 External Control Inputs (E.C.I.) or front key in optional

     4 relays can be individual programmed to relative immediate value (PV) or totalizer / batch / batch counter.

     Relative to Immediate Value (PV): Functions settable Energized Mode Hi / Lo / Hi (Lo) Hold / DO / Go, Hysteresis‚ Energized Delay, De-energized Delay, Energized latch or energized by RS485 command.

     Relative to Totalizer / Batch / Batch Counter: N / R / C mode and energized time programmable.

     3 external control input can be individual programmed for immediate value (PV) or totalizer / batch / batch counter.

     Immediate Value (PV): PV Hold / Reset for Maxi. (or Mini.) Hold / DI / Reset for Relay Energized Latch

     Totalizer / Batch / Batch Counter: Reset, Gate

     Analogue Output and Pulse Output available in option

     RS485(Modbus RTU mode), Baud Rate is up to 38400bps

     Comply to CE standard & RoHS

CS2-TM-Pulse

    Description

    The CS2-TM (Pulse Input) is innovation totalizer. ADTEK builds in high technology with wide input range from 0.01Hz~ 140.00KHz with auto-range function at same unit. There are three setting modes for K factor, 1/K factor and flow speed to match the difference output description of flow-meters. The Totalizer provides high accuracy measurement, display, control and communication (Modbus RTU mode) of Pulse from Flowmeter or encoder, proximity switch, photo switch for length control.

    There are two display screen and 3 external control input (DI) in standard and the optional 4 Relay, 1 Analogue, 1 Pulse and RS485 port available. They are also supporting fantastic control function as like as N, R, C mode for totalizer and batch control.

     

    Features

     Measuring Pulse auto range 0.01Hz~100KHz(optional:140KHz); Contact / NPN / PNP / Voltage Pulse can be switch on rear of meter

     Accuracy of immediate Value: ± 0.005%; Decimal Point auto moving according to input frequency

     Dual display screen for 10 digital Totalizer or Batch counter + 4 2/3 Immediate Value (PV) or 6 digital Batch

    programmable.

     4 relays can be individual programmed to relative immediate value (PV) or totalizer / batch / batch counter.

     Relative to Immediate Value (PV): Functions settable Energized Mode Hi / Lo / Hi (Lo) Hold / DO / Go,

    Hysteresis‚ Energized Delay, De-energized Delay, Energized latch or energized by RS485 command.

     Relative to Totalizer / Batch / Batch Counter: N / R / C mode and energized time programmable.

     3 external control input can be individual programmed for immediate value (PV) or totalizer / batch / batch

    counter.

     Immediate Value (PV): PV Hold / Reset for Maxi. (or Mini.) Hold / DI / Reset for Relay Energized Latch

     Totalizer / Batch / Batch Counter: Reset, Gate

     Analogue Output and Pulse Output available in option

     RS485(Modbus RTU mode), Baud Rate is up to 38400bps

     Comply to CE standard & RoHS

CS1-8

    Description

    CS1-8 has been designed for remote display by RS485 (Modbus RTU Mode) interface

A6-PR

    Description

    A6-PR 6 Digits Process Meter has been designed with high accuracy measurement, 6-digit display, flexible I/O functions and communication port for process measuring application.

    There are also build in 4x External Control Inputs, and can option 4x Relay outputs, 1x Analog output and 1x RS485 (Modbus RTU Mode) communication port with multi-functions such as control, alarm, re-transmission and communication for a wide range of industrial applications.

    There was designed the zero tracking and stable tracking function in programming level. According to the application, user can set the function to get the suitable reading.

     

    Features

     Measuring range: DC 0~5V/0~10V/0(4)~20mA ; Display range: 0~999999

     Programable sampling rate: 6.25~100 times/second

     Can be site calibration, input signal and input display value to execute calibration.

     Relay output can be set to HI/OK/LO , compare in period time and compare by trigger modes.

     External Control Inputs and front key can be set to zero return, tare, gross, net, start / end measuring.

     Optional analog output and RS485 communication port.

     

    Applications

     Pressure measuring and control system

     High-speed response control system

     Flow measuring and control system

     Testing equipment and testing management system

CS2-PR

    Description

    CS2-PR Process Indicator has been designed with high accuracy measurement, display and communication of DC signal 0~10V and 4(0) ~20mA with square root function. They are also built in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of industrial applications.

     

    Features

     Measuring linear signal 0~10V and 0(4)~20mA(with Square Root function) in one indicator(input code: AV)

     4 relays can be programmed individual to be a Hi / Lo / Hi Latch / Lo Latch / Go energized with Start Delay / Hysteresis / Energized & De-energized Delay functions, or to be a remote control.

     Analogue output and RS 485 communication port in option

     3 external control inputs can be programmed individual to be Relative PV (Tare) / PV Hold / Maximum or Minimum Hold / DI (remote monitoring) / Reset for Relay Energized Latch….

     CE Approved & RoHS

CS1-PR

    Description

    CS1-PR economic type Process Indicator has been designed with high accuracy measurement, display and communication of DC signal 0~10V and 4(0)~20mA. They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of industrial applications.

     

    Features

     Measuring linear signal 0~10V and 0(4)~20mA in one indicator(input code: AV)

     Option available 1 of 1 relay, 1 analogue output or RS485(Modbus RTU mode)

     1 relay can be programmed individual to be a Hi / Lo / Hi Latch / Lo Latch energized with Start Delay /

    Hysteresis / Energized & De-energized Delay functions.

     Analogue output or RS 485 communication port in option

     CE Approved & RoHS

CM2-PR

    Description

    CM2-PR Process Meter has been designed in simple operation and 4 digital 20mm LED display with economic cost. They are can be programmed by buttons that are hidden in front panel. They are also available to option 2 relay output and an analog output or RS485(Modbus RTU Mode) communication.

     

    Features

     Measuring 0(1)~5V/0~10V, 0~10mA/0(4)~20mA

     Optional DC24V excitation power for 2 wire sensors

     The operation buttons are built-in to prevent users from arbitrary operation or incorrect setting, which may cause abnormal operation of the equipment

     The display value can be adjusted slightly with the "field measurement signal"

     The output can option relays and analog output or RS485 (Modbus RTU mode)

     Relay function in addition to start delay, active delay, delay off and active hold

     Analog output voltage signal range can be switched (0~10V/0~5V/1 ~5V) or current signal range can be switched (0~10mA/0~20mA/4~20mA)

     The analog output signal is free to set the corresponding display range (Span-50%) and can be fine-tuned on-site

     On board terminal design, no quality issue; installation depth is only 72mm

     

    Applications

     2 wire sensing transducers as like as pressure, level and so on…

     Process alarm or communication for data collection

CM1-PR

    Description

    CM1-PR Indicator has been designed in simple function and 4 digital 20.0mm LED displays with economic cost. They are can be programmed by tact switches that are hidden in backside of front bezel. They are also available option of 2 Relay outputs, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of industrial applications.

     

    Features

     Measuring 0(1)~5V/0~10V, 0~10mA/0(4)~20mA ( or 2 wire sensor with 24Vdc excitation supply )

     Optional DC24V excitation power for 2 wire sensors

     The operation buttons are built-in to prevent users from arbitrary operation or incorrect setting, which may cause abnormal operation of the equipment

     The display value can be adjusted slightly with the "field measurement signal"

     The output can option relays or analog output or RS485 (Modbus RTU mode)

     Relay function in addition to start delay, active delay, delay off and active hold

     Analog output voltage signal range can be switched (0~10V/0~5V/1 ~5V) or current signal range can be switched (0~10mA/0~20mA/4~20mA)

     The analog output signal is free to set the corresponding display range (Span-50%) and can be fine-tuned on-site

     On board terminal design, no quality issue; installation depth is only 72mm

     

    Applications

     2 wire sensing transducers as like as pressure, level and so on…

     Process alarm or communication for data collection

CS3-PR

    Description

    CS3-PR Process Indicator has been designed with 0~10V and 4(0)~20mA high accuracy measurement. A compact body design for small equipment, laboratory instrument, and others. Also are available with relay output, analog output, RS485 Modbus RTU communication to cover a wide range of applications.

     

    Features

     Measuring type:0~10V/0(4)~20mA

     Can be set square root display

     Relay output can be set to Hi / Lo / Hi Hold /Lo Hold / DO mode and can setting as Start delay band / Hysteresis band / Delay on & Delay off function

     Analog output or RS485 communication are optional

     External control input can be set to PV Hold / Max or Min value reset / Relay Reset

     CE and FCC approved

     

    Applications

     Control, measurement and data record by RS485

CS3S-PR

    Features

     Measuring: 0~20mA/0~10V

     Accuracy: ±0.1%

     Display range: -1999~9999

     Dimension: 1/32 DIN (48x24mm)

     High stability and reliability

A6-SG

    Description

    A6-SG weighing controller has been designed with high accuracy measurement (24bit A/D), 6 digital display, flexible I/O functions and communication port for general weighing application. They are also built in 4 Relay outputs, 4 External Control Inputs, 1 Analogue output and 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of industrial applications. They was designed the tracking zero and tracking stable function in programming level. According to the system, user can set the function to get the suitable reading. According the purpose, the 4 relays can be selected individual for feeder, discharge, peak, or alarm in 7 control modes.

     

    Features

     Measuring range -1~35mV, 0.3μV/D resolution, and the sampling rate can be set from 6.25~100 time/second

     There are two calibration modes in mV standard input and key in the number of load cell’s signal(mV/V) or counterweight with system to do the calibration

     4 relay output are not only can be set to Hi/OK/Loperiod compare and compare by trigger 3 modes, but also feeder, discharge, peak, compare during PV over the band of zero, and so on.

     4 control input can be set from terminals or front key input with zero, tare, gross, net, weighing start/end function….and so on.

     Optional re-transmission and RS485 communication port available.

     

    Applications

     Weighing machine

     Weighing check with Hi/OK/Lo

     Force testing equipment

     Filling machine

     Mixture machine

CS2-SG

    Description

    CS2-SG Strain Gauge Indicator has been designed with high accuracy measurement, display and communication of DC signal 0~1.0/~4.0mV or 0~10.0/~40.0mV as like as Load Cell or Strain Gauge.

    The meter supports Field Calibration function. It can be calibrated with sensor(Load Cell/Strain Gauge) to meet machinery structure.

    They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS-485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments applications.

     

    Features

    ■ Measuring load cell, strain gauge signal 0~1.0/~2.0/~3.33/~4.0/~10.0/~20.0/~40.0mV/V (Specified)

    ■ Field calibration with load cell or strain gauge to meet the system requirement

    ■ 4 relay can be programmed individual to be a Hi / Lo / Hi Hold / Lo Hold / Go, and can be energized with Start Delay / Hysteresis / Energized & De-energized Delay functions, or to be a remote control.

    ■ Analogue output and RS-485 communication port in option ˙

    3 external control inputs can be programmed individual to be Tare (Relative PV) / PV Hold / Maximum or Minimum Hold / DI (remote monitoring) / Reset for Relay Energized Latch….

    ■ CE Approved & RoHS

     

    Applications

    ■ Testing Equipments for weight/force Measuring, Alarm, Control and Communication with PC/PLC

    ■ Leakage testing equipment by tare and relay function.

    ■ Weighting control for packing machine, filling machine.

CS1-SG

    Description

    CS1-SG economic type strain gauge/load cell indicator is equipped with high accuracy measurement, display and communication of DC signal 0~1.0/~4.0mV or 0~10.0/~40.0mV.

    It supports field calibration, and It can calibrate with sensor (load cell/strain gauge) according to actual needs.

    It is able to select one from these three functions, 1 relay output, 1 analogue output or 1 RS-485 (Modbus RTU Mode) interface; they provides many functions such as control, alarm, re-transmission, and communication.

     

    Features

     Measuring load cell, strain gauge signal 0~1.0/~2.0/~3.33/~4.0/~10.0/~20.0/~40.0mV/V (Specified)

     Field calibration with load cell or strain gauge to meet the system requirement.

     Able to select one from these 3 functions, 1 relay output, 1 analog output, or 1 RS-485

     Relay output can be programmed individually to be a Hi / Lo / Hi Hold / Lo Hold, and can be energized with Start Delay / Hysteresis / Energized & De-energized Delay functions.

     Optional purchase: analog output or RS-485 communication port

     CE Approved & RoHS

     

    Applications

    ■ Testing Equipments for weight/force measurement; work with PC/PLC for alarm or communication

    ■ Weighting control for packing machine and filling machine

CS3-SG

    Description

    CS3-SG Strain Gauge Indicator has been designed with high accuracy measurement, display and communication of DC signal 0~1.0/~2.0/~3.0/~3.33/~4.0mV as like as Load Cell or Strain Gauge. The meter supports Field Calibration function. It can be calibrated with sensor (Load Cell/Strain Gauge) to meet machinery structure. They are also building in 2 Relay outputs, 1 External Control Input, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of machinery and testing equipment applications.

     

    Features

     Measuring load cell, strain gauge signal 0~1.0/~2.0/~3.0/~3.33/~4.0mV/V

     Field calibration with load cell or strain gauge to meet the system requirement

     2 relays can be programmed individual to be a Hi / Lo / Hi Latch / Lo Latch energized with Start Delay / Hysteresis / Energized & De-energized Delay functions, or to be a remote control.

     Analogue output or RS 485 communication port available in option

     1 external control input can be programmed to be Relative PV(Tare) / PV Hold / DI (remote monitoring) / Reset for Maximum or Minimum Hold / Reset for Relay Energized Latch….

     CE Approved & RoHS

     

    Applications

     Testing Equipment for weight/force Measuring, Alarm, Control and Communication with PC/PLC

     Leakage testing equipment by tare and relay function.

     Weighting control for packing machine, filling machine.

CS2-PM

    Description

    CS2-PM Potentiometer Indicator has been designed with high accuracy measurement, display and communication of Ohm (3 wire) as like as Positioner.  The meter supports Field Calibration function. It can be calibrated with sensor (Potentiometer) to meet machinery structure. They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipment applications.

     

    Features

     Measuring potentiometer signal 0~50Ω/~2.0KΩ; 0~2.0KΩ/~100.0KΩ (3 wire)

     Field calibration with potentiometer to meet the system requirement

     4 relays can be programmed individual to be a Hi / Lo / Hi Latch / Lo Latch / Go energized with Start Delay / Hysteresis / Energized & De-energized Delay functions, or to be a remote control.

     Analogue output and RS 485 communication port in option

     3 external control inputs can be programmed individual to be Tare (Relative PV) / PV Hold / Maximum or Minimum Hold / DI (remote monitoring) / Reset for Relay Energized Latch….

     CE Approved & RoHS

     

    Applications

    ● Testing Equipment for thickness Measuring, Alarm, Control and Communication with PC/PLC

    ● Position control for Valve, Gate or various application

CS1-PM

    Description

    CS1-PM economic type Potentiometer Indicator has been designed with high accuracy measurement, display and communication of resistance (3 wires) as like as Positioner. The meter supports Field Calibration function. It can be calibrated with sensor (Potentiometer) to meet machinery structure. They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of machinery and testing equipment applications.

     

    Features

     Measuring potentiometer signal 0~50Ω/~2.0KΩ and 0~2.0KΩ/~100.0KΩ (3 wire) changeable by dip switch on rear of meter

     Field calibration with potentiometer to meet the system requirement

     Option available 1 of 1 relay, 1 analogue output or RS485(Modbus RTU mode)

     1 relay can be programmed individual to be a Hi / Lo / Hi Latch / Lo Latch energized with Start Delay / Hysteresis / Energized & De-energized Delay functions.

     Analogue output or RS 485 communication port in option

     CE Approved & RoHS

     

    Applications

    ● Testing Equipment for thickness Measuring, Alarm, Control and Communication with PC/PLC

    ● Position control for Valve, Gate or various application

CS3-PM

    Description

    CS3-PM Potentiometer Indicator has been designed with high accuracy displaycontrollerremote communications A compact body design for small equipment, laboratory instrument, and others. Also are available with relay output, analog output, RS485 Modbus RTU communication to cover a wide range of applications.

     

    Features

     Measuring range:0~50Ω/~2.0KΩ , 0~2.0KΩ/~100.0KΩ (3 wire)

     Field calibration with potentiometer to meet the system requirement

     Relay output can be set to Hi / Lo / Hi Hold /Lo Hold / DO mode and can setting as Start delay band / Hysteresis band / Delay on & Delay off function

     Analog output or RS485 communication are optional

    External control input can be set to PV Hold / Max or Min value reset / Relay Reset

    CE and FCC approved

     

    Applications

     Testing Equipment for thickness Measuring, Alarm, Control and Communication with PC/PLC

     Position control for Valve, Gate or various application

CS2-RS

    Description

    CS2-RS Resistance Indicator has been designed with high accuracy measurement, display and communication of Ohm (2 wire) as like as Coil of motor or transformer. The meter supports Field Calibration function. It can be calibrated with sensor (Resistance) to meet machinery structure. We build flexible function as like as 3 bank (for multi-range scaling and set point) and 3 external control inputs meet to various testing equipment inquiry. They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipment applications.

     

    Features

     Measuring resistance 0~200Ω/2000Ω/20.0KΩ/200.0KΩ (2 wire)

     4 banks pre-set for difference measuring range with all relay functions relative 4 difference scaling, and selectable by 3 External Control Inputs (E.C.I.) Or front key

     Field calibration with resistance to meet the system requirement

     4 relays can be programmed individual to be a Hi / Lo / Hi Latch / Lo Latch / Go energized with Start Delay / Hysteresis / Energized & De-energized Delay functions, or to be a remote control.

     Analogue output and RS 485 communication port in option

     3 external control inputs can be programmed individual to be Tare (Relative PV) / PV Hold / Maximum or Minimum Hold / DI (remote monitoring) / Reset for Relay Energized Latch….

     CE Approved & RoHS

     

    Applications

     Testing Equipment for resistance (as like as coil of motor, transformer, relay ..) Measuring, Alarm, Control and Communication with PC/PLC.

     Components of resistance online testing station.

CS1-RS

    Description

    CS1-RS economic type Resistance Indicator has been designed with high accuracy measurement, display and communication of Ohm (2 wire) as like as Coil of motor or transformer. The meter supports Field Calibration function. It can be calibrated with sensor (Resistance) to meet machinery structure. They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of machinery and testing equipment applications.

     

    Features

     Measuring resistance 0~200Ω/2000Ω/20.0KΩ/200.0KΩ (2 wire) changeable by dip switch on rear of meter

     Field calibration with resistance to meet the system requirement

     Option available 1 of 1 relay, 1 analogue output or RS485(Modbus RTU mode)

     1 relay can be programmed individual to be a Hi / Lo / Hi Latch / Lo Latch energized with Start Delay / Hysteresis / Energized & De-energized Delay functions.

     Analogue output or RS 485 communication port in option

     CE Approved & RoHS

     

    Applications

     Testing Equipment for resistance (as like as coil of motor, transformer, relay ..) Measuring, Alarm, Control and Communication with PC/PLC.

     Components of resistance online testing station.

CS3-RS

    Description

    CS3-RS Resistance Indicator has been designed with high accuracy displaycontrolremote communication. A compact body design for small equipment, laboratory instrument, and others. Also are available with relay output, analog output, RS485 Modbus RTU communication to cover a wide range of applications.

     

    Features

     Measuring range: 0~200Ω/2000Ω/20.0KΩ/200.0KΩ (2 wire)

     Field calibration with resistance to meet the system requirement

     Relay output can be set to Hi / Lo / Hi Hold /Lo Hold / DO mode and can setting as Start delay band / Hysteresis band / Delay on & Delay off function

     Analog output or RS485 communication are optional

     External control input can be set to PV Hold / Max or Min value reset / Relay Reset

     CE and FCC approved

     

    Applications

     Testing Equipment for resistance (as like as coil of motor, transformer, relay ..) Measuring, Alarm, Control and Communication with PC/PLC.

     Components of resistance online testing station.

CS2-T

    Description

    CS2-T Temperature Indicator has been designed with high accuracy measurement, display and communication of Thermocouple or Pt100Ω. They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipment application.

     

    Features

     Measuring RTD: Pt100Ω; Thermocouple: K, J, E, T

     4 relays can be programmed individual to be a Hi / Lo / Hi Latch / Lo Latch / Go energized with Start Delay / Hysteresis / Energized & De-energized Delay functions, or to be a remote control.

     Analogue output and RS 485 communication port in option

     3 external control inputs can be programmed individual to be Relative PV (Tare) / PV Hold / Maximum or Minimum Hold / DI (remote monitoring) / Reset for Relay Energized Latch….

     CE Approved & RoHS

CS1-T

    Description

    CS1-T economic type Temperature Indicator is designed for high accuracy measurement of Thermocouple or Pt100Ω, which is with display, control and communication function.

     

    It allows one more optional function of Relay output, Analogue output, or RS-485 (Modbus RTU Mode) communication output. And that's how CS1-T provides multiple functions of control, alarm, re-transmission, or communication.

     

    Features

     Measuring RTD: Pt100Ω; Thermocouple: K, J, E, T

     Available for one more optional function: relay output, analog output, or RS-485 Modbus RTU communication output

     1 relay output can be programmed individually to be Hi / Lo / Hi Hold / Lo Hold energized with Start Delay / Hysteresis / Energized & De-energized Delay functions.

     CE Approved

CM2-TR

    CM2-TR RTD Temperature Indicator has been designed in simple operation and 4 digital 20mm LED

    display with economic cost.

    They are can be programmed by buttons that are hidden in front panel.

    They are also available to option relay output and an analog output or RS485(Modbus RTU Mode)

    communication.

CM1-TR

    Description

     

    CM1-TR RTD Temperature Meter has been designed in simple operation and 4 digital 20mm LED display with economic cost. They are can be programmed by buttons that are hidden in front panel. They are also available to option relay output and an analog output or RS485(Modbus RTU Mode) communication.

     

    Features

     Measuring RTD type: PT100Ω / PT1000Ω ˙ Unit can be set to or

     The operation buttons are built-in to prevent users from arbitrary operation or incorrect setting, which may cause abnormal operation of the equipment

     The display value can be adjusted slightly with the "field measurement signal"

     The output can option relays or analog output or RS485 (Modbus RTU mode)

     Relay function in addition to start delay, active delay, delay off and active hold

     Analog output voltage signal range can be switched (0~10V/0~5V/1 ~5V) or current signal range can be switched (0~10mA/0~20mA/4~20mA)

     The analog output signal is free to set the corresponding display range (Span-50%) and can be fine-tuned on-site

     On board terminal design, no quality issue; installation depth is only 73mm

     

     

    Applications

     With RTD (PT100Ω / PT1000Ω) sensor for temperature display and control.

     Process alarm or communication for data collection.

CS3-TR

    Description

    CS3-TR Temperature Indicator has been designed with Pt100 (3 wire) high accuracy measurement. A compact body design for small equipment, laboratory instrument, and others. Also are available with relay output, analog output, RS485 Modbus RTU communication to cover a wide range of applications

     

    Features

     Unit can be switched or

     Relay output can be set to Hi / Lo / Hi Hold /Lo Hold / DO mode and can setting as Start delay band / Hysteresis band / Delay on & Delay off function

     Analog output or RS485 communication is optional

     External control input can be set to PV Hold / Max or Min value reset / Relay Reset

     CE and FCC approved

     

    Applications

     Temperature display, control, measurement and data record by RS485

CS3S-TR

    Features

     Measuring: Pt100/Pt1000

     Accuracy: ±0.1%

     Display range: -1999~9999

     Dimension: 1/32 DIN (48x24mm)

     High stability and reliability

CM2-TC

    CM2-TC Thermocouple Temperature Indicator has been designed in simple operation and 4 digital

    20mm LED display with economic cost.

    They are can be programmed by buttons that are hidden in front panel.

    They are also available to option relay output and an analog output or RS485(Modbus RTU Mode)

    communication.

CM1-TC

    Description

    CM1-TC Thermocouple Temperature Meter has been designed in simple function and 4 digital 20.0mm LED displays with economic cost. They are can be programmed by tact switches that are hidden in front panel. They are also available to option relay output or an analog output or RS485(Modbus RTU Mode) communication.

     

    Features

     Measuring thermocouple type: KJETBRSN

     Unit can be set to or

     The operation buttons are built-in to prevent users from arbitrary operation or incorrect setting, which may cause abnormal operation of the equipment

     The display value can be adjusted slightly with the "field measurement signal"

     The output can option relays or analog output or RS485 (Modbus RTU mode)

     Relay function in addition to start delay, action delay, re-return delay: in addition, more "action hold" function

     Analog output voltage signal range can be switched (0~10V/0~5V/1 ~5V)

    or current signal range can be switched (0~10mA/0~20mA/4~20mA)

     The analog output signal is free to set the corresponding display range (Span-50%) and can be fine-tuned on-site

     The input type and display range of the thermocouple can be arbitrarily set according to the site requirements

     On board terminal design, no quality issue; installation depth is only 73mm

     

    Applications

     With thermocouple sensor for temperature display and control.

     Temperature measurement, display and communication for data collection.

CS3-TC

    Description

    CS3-TC Temperature Indicator has been designed with high accuracy measurement. A compact body design for small equipment, laboratory instrument, and others. Also are available with relay output, analog output, RS485 Modbus RTU communication to cover a wide range of applications.

     

    Features

     Measuring type: K , J , E , T , R , S , B , N

     Unit can be switched or

     Relay output can be set to Hi / Lo / Hi Hold / Lo Hold / DO mode and can setting as Start delay band / Hysteresis band / Delay on & Delay off function

     Analog output or RS485 communication are optional

     External control input can be set to PV Hold / Max or Min value reset / Relay Reset

     CE and FCC approved

     

    Applications

     Temperature display, control, measurement and data record by RS485

CS2-RL

    Description

    CS2-RL RPM Indicator has been designed with high accuracy measurement, display and communication of pulse (Frequency). The innovation feature is auto-range input from 0.01Hz~ 100KHz (option ~140KHz) and the display resolution will auto-change to show the highest according to input frequency. They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of testing and machinery control applications.

     

    Features

     Measuring Frequency AUTO RANGE 0.01~100KHz / ~140KHz(optional) / Contact, NPN, PNP, Voltage pulse can be switch on rear of meter

     Accuracy: ± 0.005%; Display range: 0~99999; Decimal Point auto moving according to input frequency

     4 relays can be programmed individual to be a Hi / Lo / Hi Latch / Lo Latch / Go energized with Start Delay / Hysteresis / Energized & De-energized Delay functions, or to be a remote control.

     Analogue output and RS 485 communication port in option

     3 external control inputs can be programmed individual to be Tare (Relative PV) / PV Hold / Maximum or Minimum Hold / DI (remote monitoring) / Reset for Relay Energized Latch….

     CE Approved & RoHS

CS1-RL

    Description

    CS1-F economic type Frequency Indicator has been designed with high accuracy measurement, display and communication of Frequency. The innovation feature is auto-range input from 0.01Hz~ 100KHz (option ~140KHz) and the display resolution will auto-change to show the highest according to input frequency. They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of panels and testing applications.

     

    Features

     Measuring Frequency AUTO RANGE 0.01~100KHz / ~140KHz (optional) / Voltage pulse or sine wave (specify).

     Accuracy: ± 0.005%; Display range: 0~99999; Decimal Point auto moving according to input frequency

     Option available 1 of 1 relay, 1 analogue output or RS485(Modbus RTU mode)

     1 relay can be programmed individual to be a Hi / Lo / Hi Latch / Lo Latch energized with Start Delay / Hysteresis / Energized & De-energized Delay functions.

     Analogue output or RS 485 communication port in option

     CE Approved & RoHS

     

    Applications

     RPM, Linear line speed of Machinery Measuring, Alarm or Communication with PC/PLC

     Testing Equipment for Frequency Measuring, Alarm or Communication

CM1-RL

    Description

    CM1-RL series provides a simple economic programmable speed/velocity table, it 20.0mm, 5-digit LED display, press the key to set the display range and its anti-jamming design and reliable quality, simple installation, you can meet the needs of general measurement of speed/velocity. This instrument also has 2 group relay outputs, 1 analog output, or 1 groups RS485 (Modbus RTU mode) communication features three a (More features please refer to page description). Operation press the inner design, the more human-no action can be avoided, especially suitable for all kinds of machinery used.

     

    Features

     Free input frequency of 1Hz~6KHz, does not need to specify the frequency range input mode (NPN, PNP, and forth.) and pulse dial switch level by means of direct switch

     Purchase 2 to attach three to choose a group of relay outputs, 1 analog output, or 1 groups RS485 (Modbus RTU mode) communication

     Operation presses the inner (in front), according to field requirements set display scope; Terminal straight into design, bad problem-free installation depth only 72mm

     

    Applications

     Tie in with the adjacent switches, photoelectric switch speed/wire speed display, control and RS485 data collection

CS3-RL

    Description

    CS3-RL indicator was designed with high accuracy measurement of pulse and frequency. The innovation feature is input from 0.01Hz~100KHz the display resolution will auto-range according input frequency to shift decimal point. A compact body design for small equipment, laboratory instrument, and others. Also are available option relay output, analog output, RS485 Modbus RTU communication for most popular applications

     

    Features

     Measuring frequency 0.01Hz~100KHz can be auto-range, decimal point auto shift

     Multiple input type, Contact, NPN, PNP, Voltage pulse etc.

     Relay output can be set to Hi / Lo / Hi Hold / Lo Hold / DO mode and can setting as Start delay band / Hysteresis band / Delay on & Delay off function

     Analog output or RS485 communication are optional

     External control input can be set to PV Hold / Max or Min value reset / Relay Reset function

     CE and FCC approved

     

    Applications

     With proximity and photoelectric switches both are supporting of speed, line speed display, control, measurement and data collection via RS485.

CS2-CT

    Description

    The CS2-CT provides high speed and multifunction, counting, control and communication (Modbus RTU mode) of Pulse from flow meter or encoder, proximity switch, photo switch for length control. There are 3 external control input (DI) in standard and the optional 4 Relay, 1 Analogue, and RS485 port available. They are also supporting N, R, C mode for totalizer control.

     

    Features

     Measuring Pulse 0.01Hz~8KHz; Contact / NPN / PNP / Voltage Pulse can be switch on rear of meter

     4 banks pre-set for all relay functions relative 4 difference application, and selectable by 3 External Control Inputs (E.C.I.) or front key in optional

     4 relays can be individual programmed for N/R/C mode and energized time

     3 external control input can be individual programmed for Reset, Gat

     Analogue Output and RS485(Modbus RTU mode) available in option

     Comply to CE standard & RoHS

     

    Applications

     For Proximity switches, photoelectric sensors, encoder etc.. Counting Up/Down, length, positioning, batch display, External Control input and remote terminal communication ability

     Electrical cable machinery, paper printing machinery…

CM1-CT

    Description

    CM1-CT multifunction counter(position) display controller, is design to have 2 pulse input, for proximity switch, photoelectric sensor, encoder etc.. Counting increase or decrease, positioning batch count etc.. display, with External input and Modbus communication port. Multiple types of input mode, trip mode setting to fulfil easy usage and requirement for counter controller. For different requirement, the meter can be with 2 relay or 1 Analogue output or 1 RS485(Modbus RTD mode) communication. (Choose 1 kind of output from the 3 options)

     

    Features

     Measuring Pulse 0~5Khz (A/B phase, 2.5Khz per phase); Mechanical contact/NPN/PNP/Voltage pulse etc.. Input type can be programmable via Dip Switch setting

     5 counting mode (Counting up, Counting down, Counting Up and Down, each phase counting Up or down and phase different up or down, setting via programming

     When measuring length, set meter pulse per unit (PPR), the diameter (Diame), and the constant (Cnt.SF), the meter automatic calculates and display accumulated length

     When option 2 relays, the relay can be set to totalize value or present value, totalize value output come in various mode N/R/C/E/F/Q or Phase different input position or length, high/low alarm mode

     2 External control input, use for Reset or Gate function Choose 1 kind of output from the 3 options, 2 Relays or 1 Analogue output or 1 RS485(Modbus RTD mode) Communication

     

    Applications

     For Proximity switches, photoelectric sensors, encoder etc.. Counting Up/Down, length, positioning, batch display, External Control input and remote terminal communication ability

     Electrical cable machinery, paper printing machinery…

CS2-MC

    Description

    The CS2-MC provides dual input (A/B phase) and display with high speed, counting, control and communication (Modbus RTU mode) of Pulse from encoder, proximity switch, photo switch or flow meter for counting, length and position control. There are 3 external control input (DI) in standard and the optional 4 Relay, 1 Analogue, and RS485 port available. The relays are also supporting N, C, R, E mode and Hi/Lo energized for batch / totalizer and position control.

     

    Features

     Measuring Pulse 0.01Hz~6KHz (A/B phase: 3KHz for each channel); Contact / NPN / PNP / Voltage Pulse can be switch on rear of meter

     Double figurescan be set to display the Totalizer BatchBatch count

     CS2-MC Multifunction Counter design of the two groups pulse signal input, coupled with Proximity switch, Photoelectric sensor, Encoder ... .... etc., execution count (plus / less count), location-based, batch and other displays, control, and remote communication capabilities

     4 relays can be individual programmed for N/R/C/E/do mode with timer function

     3 external control input can be individual programmed for Reset, Gat of totalizer and/or batch

     Analogue Output and RS485(Modbus RTU mode) available in option

     

    Applications

     With the proximity switches, photoelectric switches, encoders ...etc., do the count (plus / less count), length, location, location, batch etc. displays, control, and remote communication capabilities.

CSS-4/5

    Features

     Measuring DCA, DCV, ACA, ACV, Hz

     Process signal mA, Vdc, Strain Gauge, Potentiometer, Pt100Ω

     High accuracy and resolution

     User function, easily programmed from the front panel by push-button, and set-point by Dip-Switch

     Modular design, and popular input range programmable

     Three relay ( Hi / Low / Go ) outputs

     Optional excitation supply available

CSN Series

    Description

    CSN Series is a simple type of economic Panel Meter, and its large LED display with 20.0mm and anti-jamming design, quality, reliable, easy to install. Full range can be specified DC voltage / current, thermal resistance, potentiometer, such as the general measurement requirements.

     

    Features

     Users can adjust the zero point. coarse adjustment and fine adjustment 3 potentiometer, directly in the field to adjust the displayed value

     20.0mm large highlight LED display; design of Straight into the terminal, no access to undesirable questions; Installation depth of only 73mm

CM1-TX5

    Features

     RS-485 Modbus RTU protocol (with communication LED indicator) ˙ RS-485 address 1~255

     Communication Baud rate 9600, 19200, 38400, 57600, 115.2K

     Parity check N81, N82, E81, O81

     Input 5 channels of signal selectablethermocouple/PT100

     5 channels of input can be set to play 1~10 seconds loop display

     1~5 channels of display value limits can be set, and the number of channels of carousel display screens can be set by yourself

     5 channels of input signals with LED unit cycle display

     Standard 2 groups of alarms Hi, LO with communication LED indicators to ensure the normal operation of the field system

     Suitable for HVAC refrigeration and air conditioning PLC, DDC, PC brands to achieve remote real-time monitoring

     Can be used in solar panels, medical control, clean room, ice water host, boiler, motor, chemical plant, power plant, school energy-saving control, remote control of power monitoring panel

X
Member Login

Forgot your password?
X
Login

Forgot your password?